The trend system described here operates under the TSENTRY real time control system. It is a data collection system that supports the following functions:
...
Expand | ||
---|---|---|
| ||
The following screens are available as part of the Trend System:
|
...
Expand | ||
---|---|---|
| ||
A historical trend trigger is the definition of an event along with a list of data to be recorded when that event is triggered. An event is triggered when a set of variables meet some prescribed conditions. In an aluminum smelting plant, for instance, a trigger could be defined to capture data during an anode effect. The trigger could watch for when the pot resistance gets too high, and when it does record a set of data including the pot resistance, volts, and line amps. Once this trigger is configured in the historical trend system, all anode effect events would be captured to individual historical trend files on disk for later review. Once a trigger has been activated, the historical trend trigger system monitors each of the trigger conditions and continuously evaluates each of them to determine when they have all been met. During this time the trigger is Waiting for trigger event detection. If this occurs, and all trigger conditions are met, then data collection begins and the trend system begins to write data to the file. This will continue until the trigger conditions are no longer all met. At this point the data file is closed and left on the disk for later review. Several options are available to enhance data collection:
Triggers can be created, modified, activated, and deactivated using the TriggerMgr [LINK] screen. |
Expand | ||
---|---|---|
| ||
Historical trigger files are stored on the host as ASCII text files. Following is an example file:
|
...
Expand | ||
---|---|---|
| ||
MenuIn the bottom left of the display is a button labeled Menu. Clicking this button will navigate back to the most recent menu screen. TriggerMgrIn the bottom left of the display is a button labeled TriggerMgr. Clicking this button will display the TriggerMgr screen pre-loaded with a trigger definition created from the current TrendX screen configuration. That is, all trended variables shown on the TrendX screen will be added in the trigger Trend list. TrendSet Loader ControlTo the right of the TriggerMgr button are a set of buttons used to create, load, save, and delete TrendSets. A TrendSet is a configuration file stored on the host system that contains all of the configuration parameters for the current trend display. This allows the user to configure a trend graph, including all of the display variables and axis parameters, and store it on the host for later use. This control panel is described in detail in the TrendSetLoader [LINK] section of this manual. Trend Playback ControlsTo the right of the TrendSet loader control is the TrendPlayback control used to control the playback speed and direction of the trended data. This control panel is described in detail in the TrendPlayback [LINK] section. Reset CursorsTo the right of the trend playback controls is a button labeled Reset Cursors. Clicking this button will move the two data cursors to the far right and far left edges of the current trend view. This is helpful for regaining access to the cursors while zoomed in to a small section of the trended data. |
...